RKD 2,5 BG

Art.-Nr. 1206.2

Double-level terminal, Screw connection, Mounting type:Mounting rail TS 35/7.5 and TS 32, Rated cross-section: 2.5 mm², Width: 5 mm, Colour: Beige

Download datasheet

Details

Commercial data

General

Colour
Beige
Country of origin
CZ
Customs number
85369010
Packaging unit
100
Product description
Double-level terminal
Quantity unit
PC
Unit of weight
G
Weight per piece (including packaging)
11 g
Weight per piece (not including packaging)
10.2 g
Technical data

Dimensions

Height TS 32
65.5 mm
Height TS 35/7.5
61 mm
Length
60.2 mm
Width
5 mm

Ratings

Contamination degree
3
Maximum power dissipation for nominal condition
1.54 W
Overvoltage category
III
Rated cross-section
2.5 mm²
Rated current
24 A
Rated impulse voltage
6 kV
Rated voltage
500 V

Connection data

Connection position
Lateral
Connection principle
Screw connection
Connections
2 x 2
Number of levels
2
Number of terminals per level
2
Screw head
Slotted
Screw threading
M 2,5
Stripping length
7 mm
Tightening torque, max.
0.8 Nm
Tightening torque, min.
0.4 Nm
Wire cross-section AWG, max.
14
Wire cross-section AWG, min.
22
Wire cross-section single core (rigid)/stranded, max.
4 mm²
Wire cross-section single-core (rigid) / stranded, min.
0.2 mm²
Wire cross-section stranded with wire-end ferrules, max.
2.5 mm²
Wire cross-section stranded with wire-end ferrules, min.
0.2 mm²
Wire cross-section stranded, max.
4 mm²
Wire cross-section stranded, min.
0.2 mm²

Further technical data

End plate required
Gauge plug acc. to EN 60 947-1
A3
Mounting type
Mounting rail TS 35/7.5 and TS 32
Number of cross-connection channels
2
Number of test pick-off options
1

Materials

Flammability class UL 94
V-2
Insulation housing
Polyamide 6.6
Working temperature, max.
105 °C
Working temperature, min.
-40 °C
Authorisations

Standards and regulations

EAC approval
TR ZU 004/2011
EAC approval granted

KEMA KEUR approval

KEMA KEUR approval
EN 60947-7-1:2009
KEMA KEUR approval granted
KEMA rated current
24 A
KEMA rated impulse voltage
6 kV
KEMA rated voltage
500 V
KEMA wire cross-section single core (rigid), min.
0.2 mm²
KEMA wire cross-section single-core (rigid), max.
4 mm²
KEMA wire cross-section stranded, max.
4 mm²
KEMA wire cross-section stranded, min.
0.2 mm²

UL Recognized

UL Recognized
1
UL Usegroup C: rated current
20 A
UL Usegroup C: rated voltage
300 V
UL approval
UL 1059
UL factory wiring
UL field wiring
UL torque
5.3 Lb In
UL wire cross-section single-core (rigid) AWG, max.
12
UL wire cross-section single-core (rigid) AWG, min.
22
UL wire cross-section stranded AWG, max.
12
UL wire cross-section stranded AWG, min.
22
UL wire material
Cu
Environment

Environmental Product Compliance

REACH Candidate Substance Note
𐄂
REACH Conform
REACH Reference date
2024-11-07
RoHS Conform
Download
File
Type
Size
Filetime
STP
2 MB
23.02.2025
PDF
516 KB
24.02.2025

Accessories

Results
End plate
Insulation plate
End stop
Markers
Testadapter