SIK 10/ST BG
Art.-Nr. 17042.2
Fused terminal with disconnect plug, Screw connection, Mounting type:Mounting rail TS 35/7.5 and TS 32, Rated cross-section: 10 mm², Width: 8 mm, Colour: Beige
Download datasheetDetails
Commercial data
General
- Colour
- Beige
- Country of origin
- CZ
- Customs number
- 85369010
- GTIN (EAN)
- 4044211155797
- Packaging unit
- 25
- Product description
- fused terminal
- Quantity unit
- PC
- Unit of weight
- G
- Weight per piece (including packaging)
- 27.8 g
- Weight per piece (not including packaging)
- 25.2 g
Technical data
Dimensions
- Height TS 32
- 69 mm
- Height TS 35/7.5
- 73 mm
- Length
- 60 mm
- Width
- 8 mm
Ratings
- Contamination degree
- 3
- Overvoltage category
- III
- Rated cross-section
- 10 mm²
- Rated current (as fuse-disconnect terminal)
- 10 A
- Rated impulse voltage
- 8 kV
- Rated voltage (determined by the illuminated display and fuse being used)
- 500 V
Connection data
- Connection position
- Lateral
- Connection principle
- Screw connection
- Connections
- 2 / disconnect-plug
- Number of levels
- 1
- Number of terminals per level
- 2
- Screw head
- Slotted
- Screw threading
- M 4
- Stripping length
- 12 mm
- Tightening torque, max.
- 2 Nm
- Tightening torque, min.
- 1.2 Nm
- Wire cross-section AWG, max.
- 8
- Wire cross-section AWG, min.
- 22
- Wire cross-section single core (rigid)/stranded, max.
- 10 mm²
- Wire cross-section single-core (rigid) / stranded, min.
- 0.2 mm²
- Wire cross-section stranded with wire-end ferrules, max.
- 10 mm²
- Wire cross-section stranded with wire-end ferrules, min.
- 0.2 mm²
- Wire cross-section stranded, max.
- 10 mm²
- Wire cross-section stranded, min.
- 0.2 mm²
Further technical data
- End plate required
- ✓
- Fuse size
- 5 x 20 / 5 x 25 / 5 x 30 mm
- Gauge plug acc. to EN 60 947-1
- A5
- Mounting type
- Mounting rail TS 35/7.5 and TS 32
- Version of fuse cartridge
- G fuse 5x20 / 5x25 / 5x30
- Version of fuse holder
- Swivelling
- Voltage fuse
- 250 V
Materials
- Flammability class UL 94
- V-2
- Insulation housing
- Polyamide 6.6
- Working temperature, max.
- 105 °C
- Working temperature, min.
- -40 °C
Authorisations
Standards and regulations
- EAC approval
- TR ZU 004/2011
- EAC approval granted
- ✓
- Nemko approval
- EN 60947-7-3:2002
- Nemko approval granted
- ✓
cUL Recognized
- cUL Recognized
- 1
- cUL Usegroup B: rated current
- 10 A
- cUL Usegroup B: rated voltage
- 600 V
- cUL Usegroup C: rated current
- 10 A
- cUL Usegroup C: rated voltage
- 600 V
- cUL approval
- C22.2 No 158
- cUL torque
- 16 Nm
- cUL wire cross-section single-core (rigid) AWG, max.
- 12
- cUL wire cross-section single-core (rigid) AWG, min.
- 22
- cUL wire cross-section stranded AWG, max.
- 12
- cUL wire cross-section stranded AWG, min.
- 22
- cUL wire material
- Cu
KEMA KEUR approval
- KEMA KEUR approval
- EN 60947-7-3:2009
- KEMA KEUR approval granted
- ✓
- KEMA fuse size
- 5 x 20 / 5 x 25 / 5 x 30 mm
- KEMA power loss in compound arrangement - only short-circuit protection, max.
- 4 / 6,3 W / A
- KEMA power loss in compound arrangement - overload and short-circuit protection, max.
- 2,5 / 6,3 W / A
- KEMA power loss in singular arrangement - only short-circuit protection, max.
- 4 / 10 W / A
- KEMA power loss in singular arrangement - overload and short-circuit protection, max.
- 2,5 / 6,3 W / A
- KEMA rated current
- 10 A
- KEMA rated impulse voltage
- 8 kV
- KEMA rated voltage
- 500 V
- KEMA torque, max.
- 2 Nm
- KEMA torque, min.
- 12 Nm
- KEMA voltage fuse, max.
- 250 V
- KEMA wire cross-section single core (rigid), min.
- 2 mm²
- KEMA wire cross-section single-core (rigid), max.
- 10 mm²
- KEMA wire cross-section stranded, max.
- 10 mm²
- KEMA wire cross-section stranded, min.
- 2 mm²
UL Recognized
- UL Recognized
- 1
- UL Usegroup B: rated current
- 10 A
- UL Usegroup B: rated voltage
- 600 V
- UL Usegroup C: rated current
- 10 A
- UL Usegroup C: rated voltage
- 600 V
- UL approval
- UL 1059
- UL factory wiring
- ✓
- UL field wiring
- ✓
- UL torque
- 16 Lb In
- UL wire cross-section single-core (rigid) AWG, max.
- 12
- UL wire cross-section single-core (rigid) AWG, min.
- 22
- UL wire cross-section stranded AWG, max.
- 12
- UL wire cross-section stranded AWG, min.
- 22
- UL wire material
- Cu
German Lloyd approval
- DNV GL Certificate number
- TAE00002JJ
- DNV GL Location Classes
- Temperature: B, Humidity: B, Vibration: A
- DNV GL approval granted
- 1
- DNV GL rated cross-section
- 10 mm²
- DNV GL rated current
- 10 A
- DNV GL rated voltage
- 500 V
- DNV GL test standard
- IEC 60947-7-3:2002
Environment
Environmental Product Compliance
- REACH Candidate Substance Note
- 𐄂
- REACH Conform
- ✓
- REACH Reference date
- 2025-01-21
- RoHS Conform
- ✓
Download
File
Type
Size
Filetime
Accessories
Results
LED status display
End plate
Insulated external cross-connector
Screwdriver
End stop
Quick marking
Solid link
Connecting sleeve
Connecting piece
You have agreed to the storage of data Customize
Important notice
For your own safety, please switch to an up-to-date browser in order to be able to make full use of our services.
Your web browser is outdated and contains open security vulnerabilities
To ensure the security of your data, some functions on our website may not be accessible with your browser.
For your own safety, please switch to an up-to-date browser in order to be able to make full use of our services.
Microsoft Edge
Successor to Internet Explorer
Google Chrome
Mozilla Firefox