SVB 125 LG
Art.-Nr. 1741.0
Screw-distributor block, Screw connection, Mounting type:Mounting rail TS 35/7.5 and mounting surface, Rated cross-section of input: 16 and 35 mm², Rated cross-section of output: 16 mm², Colour: Light grey
Download datasheetDetails
Commercial data
General
- Colour
- Light grey
- Country of origin
- FR
- Customs number
- 85369010
- Packaging unit
- 1
- Product description
- Screw-type distribution block
- Quantity unit
- PC
- Unit of weight
- G
- Weight per piece (including packaging)
- 144.6 g
- Weight per piece (not including packaging)
- 136.6 g
Technical data
Dimensions
- Height
- 47 mm
- Height TS 35/7.5
- 50 mm
- Length
- 75 mm
- Width
- 27 mm
Ratings
- Contamination degree
- 3
- Input A: rated cross-section
- 35 mm²
- Input B: rated cross-section
- 16 mm²
- Maximum power dissipation for nominal condition
- 4 W
- Output: rated cross section
- 16 mm²
- Overvoltage category
- III
- Rated current Cu
- 125 A
- Rated impulse voltage
- 2,5 kV
- Rated voltage AC
- 1000 V
- Rated voltage DC
- 1500 V
Connection data
- Connection principle
- Screw connection
- Connections
- 8
- Input A: diameter
- 10 mm²
- Input A: screw head
- Inner hex (Allen)
- Input A: screw threading
- M 8
- Input A: stripping length
- 16 mm
- Input A: torque, max.
- 5 Nm
- Input A: torque, min.
- 3.5 Nm
- Input A: wire cross-section AWG, max.
- 2
- Input A: wire cross-section AWG, min.
- 8
- Input A: wire cross-section rigid, max.
- 35 mm²
- Input A: wire cross-section rigid, min.
- 10 mm²
- Input A: wire cross-section stranded, max.
- 35 mm²
- Input A: wire cross-section stranded, min.
- 10 mm²
- Input A: wire cross-section, stranded with wire-end ferrules, max.
- 35 mm²
- Input A: wire cross-section, stranded with wire-end ferrules, min.
- 10 mm²
- Input B: diameter
- 7 mm²
- Input B: screw head
- Inner hex (Allen)
- Input B: screw threading
- M 6
- Input B: stripping length
- 15 mm
- Input B: torque, max.
- 5 Nm
- Input B: torque, min.
- 3.5 Nm
- Input B: wire cross-section rigid, max.
- 16 mm²
- Input B: wire cross-section rigid, min.
- 2.5 mm²
- Input B: wire cross-section stranded with wire-end ferrules, max.
- 16 mm²
- Input B: wire cross-section stranded, max.
- 16 mm²
- Input B: wire cross-section stranded, min.
- 2.5 mm²
- Input B: wire cross-section, stranded with wire-end ferrules, min.
- 2.5 mm²
- Number of inputs A
- 1
- Number of inputs B
- 1
- Output: diameter
- 6.5 mm
- Output: screw head
- Slotted / cross recess
- Output: screw threading
- M 5
- Output: stripping length
- 12 mm
- Output: torque, max.
- 3 Nm
- Output: torque, min.
- 2 Nm
- Output: wire cross-section rigid AWG, max.
- 4
- Output: wire cross-section rigid AWG, min.
- 14
- Output: wire cross-section rigid, max.
- 16 mm²
- Output: wire cross-section rigid, min.
- 2.5 mm²
- Output: wire cross-section stranded AWG, max.
- 4
- Output: wire cross-section stranded AWG, min.
- 14
- Output: wire cross-section stranded, max.
- 16 mm²
- Output: wire cross-section stranded, min.
- 2.5 mm²
- Output: wire cross-section stranded, with wire-end ferrules AWG, max.
- 4
- Output: wire cross-section stranded, with wire-end ferrules AWG, min.
- 14
- Output: wire cross-section stranded, with wire-end ferrules, max.
- 16 mm²
- Output: wire cross-section stranded, with wire-end ferrules, min.
- 2.5 mm²
Further technical data
- Mounting type
- Mounting rail TS 35/7.5 and mounting surface
- Req. Series fuse class J
- 125 A
- SCCR rating
- 100
- Short-circuit current resistance ICW over 1 s
- 4,2 kA
- Short-circuit current resistance IPK (peak value)
- 30 kA
Output data
- Number of outputs
- 6
Materials
- Flammability class UL 94
- V-0
- Insulation housing
- Polyamide 6.6
- Working temperature, max.
- 120 °C
- Working temperature, min.
- -40 °C
Authorisations
Standards and regulations
- EAC approval
- TR ZU 004/2011
- EAC approval granted
cUL Recognized
- E95701
- cUL Recognized
- 1
- cUL Usegroup B: rated current
- 115 A
- cUL Usegroup B: rated voltage
- 600 V
- cUL Usegroup C: rated current
- 115 A
- cUL Usegroup C: rated voltage
- 600 V
- cUL approval
- C22.2 No 158
- cUL input: wire cross-section AWG, max.
- 2
- cUL input: wire cross-section AWG, min.
- 8
- cUL output: wire cross-section AWG, max.
- 4
- cUL output: wire cross-section AWG, min.
- 14
- cUL torque input
- 3.5 Nm
- cUL torque output
- 2 Nm
- cUL wire material
- Cu
UL Recognized
- UL File Number
- E95701
- UL Recognized
- 1
- UL SCCR rating
- 100 kA
- UL Usegroup B: rated current
- 115 A
- UL Usegroup B: rated voltage
- 600 V
- UL Usegroup C: rated current
- 115 A
- UL Usegroup C: rated voltage
- 600 V
- UL approval
- UL 1059
- UL factory wiring
- UL field wiring
- UL input: wire cross-section AWG, max.
- 2
- UL input: wire cross-section AWG, min.
- 8
- UL output: wire cross-section AWG, max.
- 4
- UL output: wire cross-section AWG, min.
- 14
- UL overvoltage protection - req. Series fuse class J
- 125 A
- UL torque input
- 31 Lb In.
- UL torque output
- 17.5 Lb In.
- UL wire material
- Cu
Environment
Environmental Product Compliance
- REACH CAS 1 Number
- 7439-92-1
- REACH CAS 1 Percent maximum
- 4 %
- REACH CAS 1 Percent minimal
- 0.1 %
- REACH CAS 1 Substance
- LEAD
- REACH Candidate Substance Note
- 𐄂
- REACH Conform
- 𐄂
- REACH Reference date
- 2024-06-27
- RoHS Conform
- ✓
- RoHS Exception rule
- 6c
- SCIP
- 48bc6707-7145-4463-a560-7ebe69fabaae
Download
You have agreed to the storage of data Customize
Important notice
For your own safety, please switch to an up-to-date browser in order to be able to make full use of our services.
Your web browser is outdated and contains open security vulnerabilities
To ensure the security of your data, some functions on our website may not be accessible with your browser.
For your own safety, please switch to an up-to-date browser in order to be able to make full use of our services.
Microsoft Edge
Successor to Internet Explorer
Google Chrome
Mozilla Firefox